Vivotek 3GPP User Manual Page 142

  • Download
  • Add to my manuals
  • Print
  • Page
    / 148
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 141
VIVOTEK
142 - User's Manual
data <hex decimal data>[,<hex
decimal data>]
T
he <hex decimal data> is a series of digits from 0 ~ 9, A ~ F.
Each comma separates the commands by 200 milliseconds.
flush yes,no yes: Receive data buffer of the COM port will be cleared before
read.
no: Do not clear the receive data buffer.
wait 1 ~ 65535 Wait time in milliseconds before read data.
read 1 ~ 128
T
he data length in bytes to read. The read data will be in the
return page.
Return:
HTTP/1.0 200 OK\r\n
Content-Type: text/plain\r\n
Content-Length: <system information length>\r\n
\r\n
<hex decimal data>\r\n
Where hexadecimal data is digits from 0 ~ 9, A ~ F.
8.11 Storage managements
(capability.storage.dbenabled=1)
Note: This request requires administrator privileges.
Method: GET and POST
Syntax:
http://<servername>/cgi-bin/admin/lsctrl.cgi?cmd=<cmd_type>[&<parameter>=<value>…]
The commands usage and their input arguments are as follows.
PARAMETER VALUE DESCRIPTION
cmd_type <string> Required.
Command to be executed, including search, insert, delete, update, and
queryStatus.
Command: search
PARAMETER VALUE DESCRIPTION
label <integer primary
key>
Optional.
The integer primary key column will automatically be assigned a
unique integer.
triggerType <text> Optional.
Page view 141

Comments to this Manuals

No comments