Vivotek AE-234 Installation Guide Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 6
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
3
English
Physical description
II
13
14
15 16
17
12
11
1
2
3
7
8
9 10
4
6
5
1. Lens cap with heater 2. IR LEDs behind temper glass
3. IR board and IR board bracket 4. Thermostat switch
5. Day/Night trigger: controls the color/mono
mode switch for D/N cameras
6. Universal IR control circuit board: to
control color/mono switching and IR on/off
synchronization
7. Camera bracket 8. Heater
9. Power Supply Unit: AC90~240V power input,
DC12V output
10. Blower and blower bracket
11. Fuse holder: with a 250V/5A fuse 12. AC IN terminal block: AC 90~240V external
power input.
13. OUTPUT_1 spare terminal block: for AC 24V
or AC 90~240V camera use
14. OUTPUT_2: to power supply unit
15. VR: to adjust the Infrared LED activation level 16. Thermostat switch: turn on at 35°C and turn
off at 25°C for blower
17. Ground wire: to top cover
Page view 2
1 2 3 4 5 6

Comments to this Manuals

No comments