camctrltunnel <boolean> 6/7 Indicate whether to support the http
tunnel for camera control
connection_st
atus
<boolean> 6/6 Current connection status.
0 => connect fail
1 => connect success
connection_fo
rmer
<boolean> 6/6 Previous connection status.
0 => connect fail
1 => connect success
Group: system
NAME VALUE SECURITY
(get/set)
DESCRIPTION
hostname string[40] 6/6 host name of server
(Network Camera,
Wireless Network Camera,
Video Server,
Wireless Video Server)
date <yyyy/mm/dd>,
keep,
auto
6/6 Current date of system. Set to ‘keep’
keeping date unchanged. Set to ‘auto’ to
use NTP to synchronize date.
time <hh:mm:ss>,
keep,
auto
6/6 Current time of system. Set to ‘keep’
keeping time unchanged. Set to ‘auto’ to
use NTP to synchronize time.
ntp <domain name>,
<ip address>,
<blank>
6/6 NTP server
timezone -12 ~ 12 6/6 time zone, 5 means GMT +5
updateinte
rval
0 ~ 2592000 6/6 0 to Disable automatic time adjustment,
otherwise, it means the seconds
between NTP automatic update interval.
restore 0,
<positive integer>
7/6 Restore the system parameters to
default value. Restart the server after
<value> seconds if <value> is positive
integer.
reset 0, -1, 7/6 Restart the server after <value>
Page view 44
1 2 ... 40 41 42 43 44 45 46 47 48 49 50 ... 55 56

Comments to this Manuals

No comments

AVLink Bollitori elettrici manuali utente

Partendo da Y

Cliccare su un alfabeto di seguito per far scorrere la lista completa dei modellif models starting with that letter

Modelli Tipo di Documento
YX-1042
Manuale di Servizio AVLink YX-1042 Service manual, 48 pagine