67
of 192.168.0.201, to set digital output to connect to NC with COMMON.
Clear data mode serial port driver
This URL applies to the attached serial port device including supported PTZ cameras or non-supported
custom camera. Note the serial port settings of custom cameras must be correctly defined in advance.
Send command to device attached to COM
/cgi-bin/senddata.cgi?data=123456, ABCDEF&flush=yes&wait=1000&read=6
This hyperlink will inform Video Server to send out binary format commands to the COM with “0x12,
0x34, 0x56” followed by “0xAB, 0xCD, 0xEF”. Each comma separates the commands by 200
milliseconds. “Flush=yes” means the receive data buffer of COM port must be cleared before read. Then
read 6 bytes after waiting for 1000 milliseconds. The read data can be up to 128 bytes and will return as
ASCII coded hexadecimal value, e.g., 0x41, 0x42, 0x43 read from COM port will show in returned
homepage as 414243 instead of ABC.
Restore factory default settings
/setup/restore.cgi
The Video Server will automatically restart after restoring factory default configurations.
Restart system
/setup/reset.cgi
Restart the Video Server without warning.
Page URL
The configuration page has a frame layout including an option list frame and an option page frame.
Referenced URLs, except for the configuration page, direct users to the option page frame only. Some
pages, like image quality setting and preset setting, are opened in new windows for preview.
These URLs can be accessed only by Administrator.