Group: recording_i<0~1>
PARAMETER VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
name string[40] NULL 6/6 Identification of this entry.
trigger schedule,
networkfail
schedule 6/6 Trigger type of this entry.
enable 0, 1 0 6/6 Enable or disable this recording.
priority 0, 1, 2 1 6/6 Indicate the priority of this
recording:
“0” indicates low priority.
“1” indicates normal priority.
“2” indicates high priority.
source <integer> 0 6/6 Indicate the source of media
stream.
0 means the first stream.
1 means the second stream and
etc.
2 means the third stream and etc.
3 means the fourth stream and etc.
limitsize 0,1 0 6/6 0: Entire free space mechanism
1: Limit recording size mechanism
cyclic 0,1 0 6/6 0: Disable cyclic recording
1: Enable cyclic recording
notify 0,1 1 6/6 0: Disable recording notification
1: Enable recording notification
notifyserver 0~31 0 6/6 Indicate which notification server is
scheduled.
One bit represents one application
server (server_i0~i4).
bit0 (LSB) = server_i0.
bit1 = server_i1.
bit2 = server_i2.
bit3 = server_i3.
bit4 = server_i4.
For example, enable server_i0,
server_i2, and server_i4 as
notification servers; the
notifyserver value is 21.
Page view 136