URL Command Document for VS8801-VVTK
40
url string[64] <blank> 6/6 The URL to connect to this camera
by express link.
7.18 System log
Group: syslog
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
enableremotelog <boolean> 0 6/6 Enable remote log.
serverip <IP address> <blank> 6/6 Log server IP address.
serverport 514, 1025~65535 514 6/6 Server port used for log.
level 0~7 6 6/6 Levels used to distinguish the
importance of the information:
0: LOG_EMERG
1: LOG_ALERT
2: LOG_CRIT
3: LOG_ERR
4: LOG_WARNING
5: LOG_NOTICE
6: LOG_INFO
7: LOG_DEBUG
7.19 camera PTZ control
Group: camctrl (capability.camctrl.httptunnel > 0)
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
enablehttptunnel <boolean> 0 4/4 Enable HTTP tunnel for
camera control.
Group: camctrl_c<0~(n-1)> for n channel product (capability.ptzenabled)
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
panspeed -5 ~ 5 0 1/4 Pan speed
tiltspeed -5 ~ 5 0 1/4 Tilt speed
zoomspeed -5 ~ 5 0 1/4 Zoom speed
focusspeed -5 ~ 5 0 1/4 Auto focus speed
preset_i<0~(npreset-1)
>_name
string[40] <blank> 1/4 Name of the preset location.