Vivotek FD8361 User Manual Page 144

  • Download
  • Add to my manuals
  • Print
  • Page
    / 159
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 143
VIVOTEK
144 - User's Manual
zoomspeed -5 ~ 5 1/7 Zoom speed
(It should be set by eCamCtrl.cgi rather than by setparam.cgi.)
autospeed 1 ~ 5 1/7 Auto pan/patrol speed
(It should be set by eCamCtrl.cgi rather than by setparam.cgi.)
Group: eptz_c<0~(n-1)>_s<0~(m-1)> for n channel product. and m is the number of streams which
support ePTZ.
PARAMETER VALUE SECURITY
(get/set)
DESCRIPTION
patrolseq string[120] 1/4 The indexes of patrol points, separated by “,
patroldwelling string[160] 1/4 The dwelling time of each patrol point, separated by “,”
i<0~19>_name string[40] 1/7 Name of ePTZ preset.
(It should be set by eCamCtrl.cgi rather than by
setparam.cgi.)
i<0~19>_pos <coordinate> 1/7 Left-top corner coordinate of the preset.
(It should be set by eCamCtrl.cgi rather than by
setparam.cgi.)
i<0~19>_size <window size> 1/7 Width and height of the preset.
(It should be set by eCamCtrl.cgi rather than by
setparam.cgi.)
Drive the Digital Output
Note: This request requires Viewer privileges.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/dido/setdo.cgi?do1=<state>[&do2=<state>]
[&do3=<state>][&do4=<state>][&return=<return page>]
Where state is 0 or 1; “0” means inactive or normal state, while “1” means active or triggered state.
PARAMETER VALUE DESCRIPTION
0 – Inactive, normal state
do<num>
0, 1
1 – Active, triggered state
return
<return page> Redirect to the page <return page> after the parameter is
assigned. The <return page> can be a full URL path or relative
path according to the current path. If you omit this parameter, it
will redirect to an empty page.