Vivotek FD8372 User Manual Page 196

  • Download
  • Add to my manuals
  • Print
  • Page
    / 200
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 195
VIVOTEK
196 - User's Manual
means inactive or normal
state while “1” means
active or triggered state.
Where "nstate" is next
state after duration.
Ex: vi0=0(200)1
Setting virtual input 0 to normal state, waiting 200
milliseconds, setting it to trigger state.
Note that when the virtual input is waiting for next state,
it cannot accept new requests.
return <return page> Redirect to the page <return page> after the request is
completely assigned. The <return page> can be a full
URL path or relative path according the current path. If
you omit this parameter, it will redirect to an empty
page.
Return Code Description
200 The request is successfully executed.
400 The request cannot be assigned, ex. incorrect parameters.
Examples:
setvi.cgi?vi0=0(10000)1(15000)0(20000)1
No multiple duration.
setvi.cgi?vi3=0
VI index is out of range.
setvi.cgi?vi=1
No VI index is specified.
503 The resource is unavailable, ex. Virtual input is waiting for next state.
Examples:
setvi.cgi?vi0=0(15000)1
setvi.cgi?vi0=1
Request 2 will not be accepted during the execution time(15 seconds).