Vivotek IP7251 Specifications Page 96

  • Download
  • Add to my manuals
  • Print
  • Page
    / 109
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 95
VIVOTEK - A Leading Provider of Multimedia Communication Solutions
96 - User's Manual
Example: Drive the digital output 0 to triggered state and redirect to an empty page
http://myserver/cgi-bin/dido/setdo.cgi?do0=1
Query status of the digital input
Note: This request requires the privilege of viewer.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/dido/getdi.cgi?[di0][&di1][&di2][&di3]
If no parameter is specified, all the status of digital input will be returned.
Return:
HTTP/1.0 200 OK\r\n
Content-Type: text/plain\r\n
Content-Length: <length>\r\n
\r\n
[di0=<state>]\r\n
[di1=<state>]\r\n
[di2=<state>]\r\n
[di3=<state>]\r\n
where <state> can be 0 or 1.
Example: Query the status of digital input 0
Request:
http://myserver/cgi-bin/dido/getdi.cgi?di0
Response:
HTTP/1.0 200 OK\r\n
Content-Type: text/plain\r\n
Content-Length: 7\r\n
\r\n
di0=1\r\n
Page view 95
1 2 ... 91 92 93 94 95 96 97 98 99 100 101 ... 108 109