PSC LVD REPORT
Product Safety Consultant Inc.
Page : 16 of 43
Issue Date:2012-10-04
Cl. Requirement - Test Result - Remark Verdict
Ref. No. : 12CE09L055 FM21001C
3.4 Disconnection from the mains supply N/A
3.4.1 General requirement Class III equipment. No direct
connection to mains.
N/A
3.4.2 Disconnect devices N/A
3.4.3 Permanently connected equipment N/A
3.4.4 Parts which remain energized N/A
3.4.5 Switches in flexible cords N/A
3.4.6 Number of poles - single-phase and d.c. equipment N/A
3.4.7 Number of poles - three-phase equipment N/A
3.4.8 Switches as disconnect devices N/A
3.4.9 Plugs as disconnect devices N/A
3.4.10 Interconnected equipment N/A
3.4.11 Multiple power sources N/A
3.5 Interconnection of equipment P
3.5.1 General requirements See below. P
3.5.2 Types of interconnection circuits SELV circuit. P
3.5.3 ELV circuits as interconnection circuits N/A
3.5.4 Data ports for additional equipment RJ-45 connector is input port. N/A