PSC LVD REPORT
Product Safety Consultant Inc.
Page : 23 of 43
Issue Date:2012-10-04
Cl. Requirement - Test Result - Remark Verdict
Ref. No. : 12CE09L055 FM21001C
5.1.8.2 Summation of touch currents from
telecommunication networks
N/A
a) EUT with earthed telecommunication ports N/A
b) EUT whose telecommunication ports have no
reference to protective earth
N/A
5.2 Electric strength N/A
5.2.1 General Class III equipment N/A
5.2.2 Test procedure N/A
5.3 Abnormal operating and fault conditions P
5.3.1 Protection against overload and abnormal
operation
See below P
5.3.2 Motors (see appended Annex B) N/A
5.3.3 Transformers
N/A
5.3.4 Functional insulation Method c) used, but due to
Components are mounted on
PCB rated V-1 or better.
No basic, supplementary or
reinforced insulation inside.
no test necessary.
P
5.3.5 Electromechanical components N/A
5.3.6 Audio amplifiers in ITE N/A
5.3.7 Simulation of faults See appended table 5.3. P
5.3.8 Unattended equipment N/A
5.3.9 Compliance criteria for abnormal operating and
fault conditions
See appended table 5.3. P
5.3.9.1 During the tests N/A
5.3.9.2 After the tests N/A