PSC LVD REPORT
Product Safety Consultant Inc.
Page : 22 of 43
Issue Date:2012-10-04
Cl. Requirement - Test Result - Remark Verdict
Ref. No. : 12CE09L055 FM21001C
5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS P
5.1 Touch current and protective conductor current N/A
5.1.1 General Class III equipment. N/A
5.1.2 Configuration of equipment under test (EUT) N/A
5.1.2.1 Single connection to an a.c. mains supply N/A
5.1.2.2 Redundant multiple connections to an a.c. mains
supply
N/A
5.1.2.3 Simultaneous multiple connections to an a.c. mains
supply
N/A
5.1.3 Test circuit N/A
5.1.4 Application of measuring instrument N/A
5.1.5 Test procedure N/A
5.1.6 Test measurements N/A
Supply voltage (V)
Measured touch current (mA)
Max. allowed touch current (mA)
Measured protective conductor current (mA)
Max. allowed protective conductor current (mA)
5.1.7 Equipment with touch current exceeding 3,5 mA N/A
5.1.7.1 General N/A
5.1.7.2 Simultaneous multiple connections to the supply N/A
5.1.8 Touch currents to telecommunication networks and
cable distribution systems and from
telecommunication networks
N/A
5.1.8.1 Limitation of the touch current to a
telecommunication network or to a cable
distribution system
N/A
Supply voltage (V)
Measured touch current (mA)
Max. allowed touch current (mA)