PSC LVD REPORT
Product Safety Consultant Inc.
Page : 21 of 43
Issue Date:2012-10-04
Cl. Requirement - Test Result - Remark Verdict
Ref. No. : 12CE09L055 FM21001C
4.7 Resistance to fire P
4.7.1 Reducing the risk of ignition and spread of flame See below. P
Method 1, selection and application of components
wiring and materials
(see appended table 4.7) P
Method 2, application of all of simulated fault
condition tests
N/A
4.7.2 Conditions for a fire enclosure See below. P
4.7.2.1 Parts requiring a fire enclosure See 4.7.2.2. N/A
4.7.2.2 Parts not requiring a fire enclosure This equipment supplied by
power adaptor which complied
with LPS and all components
mounted on PCB rated V-1 or
better, therefore no fire
enclosure required.
P
4.7.3 Materials P
4.7.3.1 General PCB rated accordingly. See
appended table 1.5.1 for
details.
P
4.7.3.2 Materials for fire enclosures No fire enclosure required. N/A
4.7.3.3 Materials for components and other parts outside
fire enclosures
P
4.7.3.4 Materials for components and other parts inside
fire enclosures
Internal components except
small parts are V-2, HF-2 or
better.
P
4.7.3.5 Materials for air filter assemblies No air filter provided. N/A
4.7.3.6 Materials used in high-voltage components No high voltage components
provided.
N/A
Comments to this Manuals