Vivotek FE8181 User Manual Page 153

  • Download
  • Add to my manuals
  • Print
  • Page
    / 240
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 152
VIVOTEK
User's Manual - 153
7.2 status
Group: status
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
videoactualmodulation
<product dependent>
ntsc,
pal
1 4/7 The actual modulation type
(videoin.type=0).
di_i<0~(ndi-1)>
<product dependent>
<boolean> 0 1/7 0 => Inactive, normal
1 => Active, triggered
(capability.ndi > 0)
do_i<0~(ndo-1)>
<product dependent>
<boolean> 0 1/7 0 => Inactive, normal
1 => Active, triggered
(capability.ndo > 0)
daynight
<product dependent>
day, night <product
dependent>
7/7 Current status of day, night.
onlinenum_rtsp integer 0 1/1 Current number of RTSP
connections.
onlinenum_httppush integer 0 1/1 Current number of HTTP
push server connections.
eth_i0 <string> <product
dependent>
1/7 Get network information
from mii-tool.
vi_i<0~(nvi-1)>
<product dependent>
<boolean> 0 1/7 Virtual input
0 => Inactive
1 => Active
(capability.nvi > 0)
7.3 digital input behavior define
Group: di_i<0~(ndi-1)> (capability.ndi > 0)
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
normalstate high,
low
high 1/1 Indicates open circuit or
closed circuit (inactive
status)
Page view 152
1 2 ... 148 149 150 151 152 153 154 155 156 157 158 ... 239 240

Comments to this Manuals

No comments